Water from condensate drain
soaked underneath the rubber mat and corroded galvanized
steel floor.
APPLICATION: Enclosed refrigerated
room
INDUSTRY: Facility Maintenance
CONTRACTOR: Phil Putnam
PROBLEM: This room was installed
as the building was completed, and walls are finished
around it. Therefore, removal for repair
was not an option. If left unchecked, the
corrosion would quickly destroy the floor. Even
galvanized steel is subject to corrosion damage.
SOLUTION: Contractor prepares
existing galvanized steel floor by vacuum grinding. This
will remove corrosion and provide optimal surface
adhesion for the industrial grade, high-performance
polymer repair coating.
 |
Belzona 3921
GSC conditioner
Belzona 3121 MR-7 membrane |
PRODUCT DETAILS: Belzona
3921 was recommended to the customer due to its
outstanding corrosion resistance. It has a high
zinc content, making it a superior primer. Belzona
3121 was selected as the final coating for its
flexibility, durability, and quick cure time. A
completely seamless liner replaces the failed galvanized
treatment. This repair will ensure a long
and trouble-free service life for the refrigerated
room.
REFERENCES: contact@imsolutionsva.com
SIMILAR PROJECTS: We have
completed similar floor coating repairs (also covering
concrete) at several locations for this customer
and numerous other customers located in the Commonwealth